A conventional fire alarm panel is a sensible choice for buildings and sites with a clear zone layout, such as workshops, warehouses, staff accommodation, offices and port facilities. Each zone covers one area, so when a detector or call point operates, the panel shows which part of the site is affected. Master Systems supplies, installs and services Haes Excel conventional fire alarm panels in the UAE, sized from 2 to 32 zones.
We can supply the panel only, or carry out the full job: survey, cabling layout, detector selection, installation, commissioning and handover documents.
The two panels cover different site sizes:
Twin-wire zones on the Excel-EN carry detectors and sounders on the same pair of cables. That cuts cabling time on smaller sites. On larger sites, up to eight Excel-32 panels can be networked, so a fire on one building shows on the panels in the others.
The Excel range is built for the people who install and maintain it, as well as for the people who respond to alarms:
The optional add-ons include a repeater panel, a remote LCD display unit, a relay and output card, and a sounder circuit extension card. A repeater or remote display is useful where the main panel sits in a plant room and the people who respond are at a gatehouse or reception.
Unwanted alarms are one of the main complaints about conventional fire alarm systems. They interrupt work, and if they keep happening, staff start ignoring the sounders. The three false alarm modes on the Excel panels let the engineer set how the panel reacts to a first signal from a detector, for example by checking the zone again before sounding a full alarm. We set these modes during commissioning to suit the area. A kitchen or workshop needs different settings from an office corridor. A manual call point always raises a full alarm.
For a new fire alarm panel in the UAE, a typical job runs like this:
If you already have a layout from a consultant, we can work from your drawings and quote against them.
Fire alarm systems need regular testing to stay reliable. We offer periodic service visits for Excel panels and other conventional systems. Each visit covers detector and call point tests, sounder checks, standby battery tests, and a review of the panel’s event log. You receive a service report after each visit, with any faults and recommended replacements listed.
How many zones do I need?
That depends on the site layout. A small workshop may need 2 to 4 zones, while a large accommodation block can need 20 or more. We work this out during the survey.
Can I add zones later?
The Excel-EN covers up to 12 zones. If a site may grow beyond that, it’s usually better to start with an Excel-32 or plan for networked panels.
Do Excel panels work with my existing detectors?
They support conventional detectors from Apollo, Hochiki and Nittan. We check the models fitted on site before reusing them.
Can one person test the system?
Yes. The one-man walk test lets a single engineer test detectors without someone standing at the panel.
Do you service fire alarm panels from other brands?
Yes. We service most conventional fire alarm systems. Send us the panel make and model when you book.
To get a quotation for a conventional fire alarm panel in the UAE, send us the site type, the approximate number of zones and any existing drawings. We’ll reply with a proposal and a quotation.
